+---------------------------------------+ | Viscometer Head | | [4-Line Digital Parameter Display] | | [Alphanumeric Control Keypad] | +---------------------------------------+ | | (Control Handle Mechanism) v +-----------(O)-----------+ | Cone Spindle Adapter | <-- Quick-release thumbscrew | [Removable Cone] | +-------------------------+ | v (Automatic Gap Positioning) +-------------------------+ | Built-in Peltier | <-- Rapid heating/cooling | Sample Plate | +-------------------------+ | +---------------------------------------+ | Heavy Base | | [Power Switch] [I/O Ports] | +---------------------------------------+ BROOKFIELD CAP 2000+
+-----------------------------------------------------------------------------+ | CAP 2000+ Series | +--------------------------------------+--------------------------------------+ | L-Series | H-Series | | (Low Temp/Visc) | (High Temp/Visc) | +--------------------------------------+--------------------------------------+ | • Temperature: 5°C to 75°C | • Temperature: 50°C to 235°C | | • Ideal for: Paints, inks, | • Ideal for: Asphalt, hot melts, | | coatings, and thin resins | coatings, and polymers | +--------------------------------------+--------------------------------------+
The CAP 2000+ offers variable speed, allowing it to operate between . Its primary advantage is integrated temperature control, enabling measurements at specific temperatures between ambient (or lower) and up to 235°C, depending on the model. Key Features: Variable Speed: 5 to 1000 RPM. Cone and Plate Geometry: Small sample volume required.
To access the official, complete operational guidelines, engineering specifications, and safety documentation provided by the manufacturer, use the following resource link: cap 2000 viscometer manual link
Before diving into the specifics, you must understand the model variants, as the manual differs depending on your serial number and model year. According to the official literature, instruments with a serial number prefix of “” use a different manual than those with the newer “ CPN ” prefix.
Features a built-in thermoelectric (Peltier) cooling/heating plate. This allows precise temperature control from 5°C to 75°C (L Series) or 50°C to 235°C (H Series).
: The instrument must stand on a flat, vibration-free surface. Adjust the feet until the spirit bubble centers perfectly. Cone and Plate Geometry: Small sample volume required
Regular maintenance is essential for accurate, reproducible data.
Set the desired temperature via the controller and allow the unit to stabilize.
While daily verification can be done in-house using standard oils, the manual recommends returning the unit to an authorized AMETEK Brookfield service center annually for full mechanical inspection and calibration certification. complete operational guidelines
Cones supplied with a new instrument are calibrated at the factory before shipment. However, you should still perform a verification check before using the instrument for the first time.
Regularly calibrate your CAP 2000+ using certified Brookfield viscosity standards to maintain accuracy.