: If a legitimate update is running in the background, it can sometimes take up to 18 hours for the temporary RAM drive to timeout and clear naturally, though a reboot is much faster.
[reflection.assembly]::LoadWithPartialName("Microsoft.UpdateServices.Administration") $wsus = [Microsoft.UpdateServices.Administration.AdminProxy]::GetUpdateServer() $wsus.GetConfiguration().RefreshNow = $false $wsus.GetConfiguration().Save() Restart-Service WSUSService Restart-Service SMS_WSUS_SYNC_MANAGER
Dell Lifecycle Update Stuck Running - Hardware & Infrastructure : If a legitimate update is running in
Do you have to the underlying database? Share public link
Think of the iDRAC's update system as a one-at-a-time assembly line. The SUP0108 error is simply its way of telling you that the assembly line is currently busy. It is a safety mechanism designed to prevent two different firmware operations from running simultaneously, which could corrupt the system. The SUP0108 error is simply its way of
Wait 5-10 minutes for the iDRAC to fully initialize before turning the server back on. Best Practices to Prevent SUP0108
Follow these solutions in order. Start with the least invasive and move to the more aggressive fixes. Best Practices to Prevent SUP0108 Follow these solutions
If the queue appears empty but the SUP0108 error persists, the iDRAC management processor itself is likely stuck in an "in-use" state. Resetting iDRAC will reboot the host operating system or affect live production workloads.
Run the following command to view all scheduled, running, or failed jobs: racadm jobqueue view Use code with caution.
Follow these methods sequentially, starting with the least disruptive out-of-band options before proceeding to physical intervention. 1. Perform an iDRAC Soft Reset
: During firmware operations, the iDRAC installer maps a temporary RAM drive onto the host operating system to extract files. If an update is interrupted, this RAM drive fails to unmount, maintaining a persistent software lock.